Описание

Function Emergency stop module
Also suited as safety gate monitor +
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
1- / 2-channel 1, 2
Output contacts max. 3 s
Thermal current Ith max. 7 A
Cross fault detection +
Nominal voltage DC +
Nominal voltage AC +
Connection PS
Width 22,5 mm
Type BG 5925
According to- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508 Output: max. 3 NO contacts, see contacts Single and 2-channel operation Line fault detection on On-button Manual restart or automatic restart, switch S2 With or without cross fault monitoring in the E-stop loop, switch S1 LED indicator for channel 1 and 2 and Power Removable terminal strips Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3 Width 22.5 mm''